C-Tec CFP 4 Zone Conventional Fire Panel
C-Tec CFP 4 Zone Conventional Fire Panel is an excellent choice for smaller buildings that require a simple, robust, and reliable fire detection system. It offers easy installation, straightforward operation, and sufficient flexibility to meet most conventional fire alarm needs.
C-Tec CFP 4 Zone Conventional Fire Panel is a reliable fire alarm control panel designed for small to medium-sized buildings. It operates as a conventional fire alarm system, where each detection zone is connected to a set of detectors and call points wired in parallel. The CFP panel series is known for its simplicity, ease of installation, and robust performance.
Features of the C-Tec CFP 4 Zone Conventional Fire Panel;
- Zones and Detection
- Supports 4 detection zones, with each zone capable of monitoring a series of conventional smoke detectors, heat detectors, and manual call points (MCPs).
- Each zone can handle up to 32 devices (detectors, call points).
- Zones are monitored for open and short circuits and use End-of-Line (EOL) resistors for circuit monitoring.
- Alarm and Indication
- Features LED indicators for fire, fault, and zone disablement for each zone.
- Common fire, fault, and power LEDs on the front panel provide quick visual status information.
- Two on-board sounder circuits to control bells, sirens, or sounders, each with separate fault monitoring and sounder delay options.
- Control and Programming
- Simple front panel controls for Reset, Silence/Resound, and Evacuate, which can be activated via a key switch to prevent unauthorized use.
- Basic programming capabilities, such as setting delays for alarm activation and configuring non-latching zones.
- Power Supply and Battery Backup
- Equipped with an integral mains-powered power supply unit (PSU) with battery charging capability.
- Supports up to 2 x 12V 3.2Ah sealed lead-acid batteries for standby power in case of mains failure, providing up to 24 hours standby and 30 minutes of alarm operation.
- Maintenance and Testing
- Maintenance Mode allows the panel to be tested without activating the full alarm system.
- Faults such as open circuits, short circuits, earth faults, and battery faults are indicated with corresponding LED lights.
- Outputs
- The panel provides relay outputs for Fire and Fault conditions for interfacing with other building management or monitoring systems.
- Additional output relays for auxiliary equipment (e.g., fire door controls, smoke vent controls).
- Ease of Installation
- Compact, wall-mounted design for easy installation.
- Clear labeling of terminals and connections for detectors, call points, sounders, and other devices.
- EOL Resistors (typically 6.8k ohm) are required for each zone and sounder circuit to ensure proper circuit monitoring.